Pass EMC D-PEMX-DY-23 Actual Free Exam Q&As Updated Dump Jun 26, 2025
Latest D-PEMX-DY-23 Actual Free Exam Updated 138 Questions
NEW QUESTION # 40
Which I/O module is supported for Fabric B?
- A. MX5000s
- B. MX5108n
- C. MX5016s
- D. MSG610s
Answer: B
NEW QUESTION # 41
What are the correct CLI commands to configure the management IP Address on either the MX9116n or the MX5108n switches running SmartFabric OS10?
- A. interface vlan 4020
no ip address
ip address 192.168.1.10/24
no shutdown
exit
management route 0.0.0.0/0 192.168.1.1 - B. interface vlan 4020
no ip address
ip address 192.168.1.10/24
no shutdown
exit
interface mgmt 1/1/1
no ip address
ip address 192.168.1.10/24
no shutdown
exit
management route 0.0.0.0/0 192.168.1.1 - C. interface vlan 4020
no ip address
ip address 192.168.10.10/24
no shutdown
exit
interface mgmt 1/1/1
no shutdown
exit
management route 0.0.0.0/0 192.168.10.1 - D. interface mgmt 1/1/1
no ip address
ip address 192.168.10.10/24
no shutdown
exit
management route 0.0.0.0/0 192.168.10.1
Answer: B
NEW QUESTION # 42
Which section of the PowerEdge MX7000 chassis provides a structure for mounting PSUs and sleds?
- A. Management Module slot
- B. Rear Tub
- C. Main Chassis
- D. Main Distribution Board
Answer: C
NEW QUESTION # 43
What types of network shares are supported for hosting the firmware catalog for a PowerEdge MX7000 chassis?
- A. SMB, SFTP, NFS, and FTP
- B. NFS, CIFS, HTTP, and HTTPS
- C. SCP, FTP, NFS, and HTTPS
- D. HTTP, HTTPS, FTP, and SFTP
Answer: B
NEW QUESTION # 44
When multiple MX9002m modules are daisy-chained to Top-of-Rack switches, which uplink port can be used for stacking?
- A. Either uplink port can be utilized
- B. Only the Gb2 port on the secondary (right) MX9002
- C. Gb1 uplink ports can only stack with other Gb2 ports
- D. Only the Gb2 port on the primary (left) MX9002
Answer: A
NEW QUESTION # 45
What is a function of the Fabric Resources Director (FReD)?
- A. Hosting OME-M interface
- B. Critical temperature monitoring
- C. SAS Expander routing for Fabric C
- D. Providing QuickSync 2 feature
Answer: B
NEW QUESTION # 46
Which MX7000 chassis components does the Vertical Power Distribution Board power?
- A. Compute sleds
Right and Left Control Panels
Rear fans - B. IOMs
Rear fans
Front fans - C. IOMs
Compute sleds
Rear fans
Answer: B
NEW QUESTION # 47
In SmartFabric mode, what is the recommended maximum number of VLANs per server port on an MX7000 switch?
- A. 0
- B. 1
- C. 2
- D. 3
Answer: A
NEW QUESTION # 48
What is the minimum OME-M version required to use ATMOS?
- A. 2.00.00
- B. 1.40.00
- C. 1.60.50
- D. 2.10.00
Answer: A
NEW QUESTION # 49
A company has several MX7000-systems, four FX2 solutions, one M1000e, and several PowerEdge rack servers.
Which management interface is recommended for managing this range of systems?
- A. OpenManage Modular with optional plugins
- B. OpenManage Essentials
- C. OpenManage Enterprise
- D. OpenManage Modular, no optional plugins required
Answer: C
NEW QUESTION # 50
What is the maximum number of mezzanine cards that can be installed in an MX840c?
- A. 0
- B. 1
- C. 2
- D. 3
Answer: B
NEW QUESTION # 51
Where are the diagnostic LEDs located on a PowerEdge MX750c compute sled?
- A. Located on the back of the sled
- B. Middle of the system board with the top of the cover removed
- C. Front of the sled after removing the bottom two drives
- D. Front of the sled after removing the top two drives
Answer: C
NEW QUESTION # 52
A field engineer needs to apply custom MAC addresses on the MX7000.
Which feature should they use?
- A. Quick deploy
- B. FlexAddress
- C. Identity Pools
- D. MCM Groups
Answer: C
NEW QUESTION # 53
How can a hard reset be performed on iDRAC?
- A. On the server, press and hold the ID LED button for 15 seconds
- B. Using the RACADM command --SystemReset -t 0 -f
- C. On the iDRAC web interface, select the Reset option
- D. Using the OME-M Interface and selecting Virtual Reseat
Answer: A
NEW QUESTION # 54
An administrator is asked to install and power on a new MX740c sled in a PowerEdge MX7000 chassis. The administrator inserts the sled and presses the power button. The power button LED is pulsating green. After a short time, the power button turns to solid green and the server turns on.
What operation was in progress when the power button was pulsating green?
- A. Management Module was updating its component inventory
- B. iDRAC was booting
- C. Lifecycle Controller was taking firmware inventory
- D. IOM was booting
Answer: B
NEW QUESTION # 55
In addition to one compute sled, one management module, and one IOM, what is the minimum required HW configuration on the PowerEdge MX7000 to POST?
- A. 3 power supply units
4 front cooling fans
5 rear cooling fans - B. 2 power supply units
4 front cooling fans
5 rear cooling fans - C. 1 power supply unit
1 front cooling fan
1 rear cooling fan - D. 1 power supply unit
2 front cooling fans
3 rear cooling fans
Answer: B
NEW QUESTION # 56
......
Online Questions - Valid Practice D-PEMX-DY-23 Exam Dumps Test Questions: https://www.verifieddumps.com/D-PEMX-DY-23-valid-exam-braindumps.html
100% Real D-PEMX-DY-23 dumps - Brilliant D-PEMX-DY-23 Exam Questions PDF: https://drive.google.com/open?id=15G6ERw-LyzDzHIbj3iMAqYyeD8m99NUc